I have continuity in both coils (AC-DC) but no power output?

I have a 12v 2A transformer without power output

I testes/checked with a voltmeter both coils (AC-DC) but no V+ output

Block Image

已回答! 显示答案 我也有这个问题

这是一个好问题吗?

得分 0
添加一条评论

2个答案

已选择的解决方案

You may have a short in your secondary winding. A short will still register as continuity, but the output side of the transformer will be effectively non-functional since it will be unable to convert the magnetic field from the primary winding into electric current.

Unfortunately these can be difficult to troubleshoot. You may be able to find some information with a web search, but it tends to get into sensitive measurement, and honestly unless you're willing to re-wind the transformer coils you're probably going to spend a lot of time (and maybe money) for little gain.

这个答案有帮助吗?

得分 1
添加一条评论

@marcosllamas "I testes/checked with a voltmeter both coils (AC-DC)" How did you test it with a voltmeter? Most transformers do not have DC but produce AC and need a rectifier circuit to produce DC. You need to give us more of the values etc. Tell us what the input voltage is and give us an idea what this transformer comes out of. If you have some sort of identifier on the transformer, that will help as well.

这个答案有帮助吗?

得分 1
添加一条评论