Unihertz Atom speaker Replacement

Test whether the speaker to answering the phone call works and change it if necessary. This guide work for Unihertz Atom, not Unihertz Atom XL or anything else.

I suspect that my speaker broken because of the water go into it.

You need a speaker fit unihertz atom's size. It should be 8*9*2.3mm (2~2.3mm). The seller said it work for another huawei phone too.

To find the speaker, I ask many cellphone parts sellers whether they have speakers in this size. Contact me if you can not find one; I still have 2 speakers.

See also:

    1. Unihertz Atom speaker Replacement, remove the rear case: 步骤 1 中的图像 1,1
      • Remove the 8 screws on the rear case and remove the rear case

      询问修复机器人

      添加评论

    2. Unihertz Atom speaker Replacement, remove the screws of the loadspeaker: 步骤 2 中的图像 1,1
      • Remove the 2 screws on the loudspeaker assembly

      询问修复机器人

      添加评论

    3. Unihertz Atom speaker Replacement, remove the loadspeaker: 步骤 3 中的图像 1,1
      • Remove the loudspeaker assembly

      询问修复机器人

      添加评论

    4. Unihertz Atom speaker Replacement, remove the battery: 步骤 4 中的图像 1,1
      • Pry open the cable interface connecting the battery and the motherboard remove the battery

      询问修复机器人

      添加评论

    5. Unihertz Atom speaker Replacement, remove the screws of the camera: 步骤 5 中的图像 1,1
      • Remove the screws on the camera assembly Pry open the cable interface at the connection between the camera assembly and the motherboard

      询问修复机器人

      添加评论

    6. Unihertz Atom speaker Replacement, remove the camera: 步骤 6 中的图像 1,1
      • Remove the camera assembly

      询问修复机器人

      添加评论

    7. Unihertz Atom speaker Replacement, replace the speaker: 步骤 7 中的图像 1,1
      • you can cee the speaker for the phone call now.

      • Test it with a Ohmmeter. Metering its resistance between left and right metal leg. If it does not make noise while metering, it was broken.

      • It was pasted on the phone; remove it with a flathead screwdriver or somewhat.

      • put the new speaker there. for me, it work fine without glue.

      询问修复机器人

      添加评论

      • put anything back.

      • Be careful while installing the camera part, the cable could fit even in a wrong position. If the camera does not work after reboot the phone, you may misarrange the cable.

      询问修复机器人

      添加评论

结论

当重新组装你的设备时,请按照说明的相反顺序进行操作。

取消:我没有完成这个指南。

作者

与

chair

于09/26/23注册

157 声望

撰写一个指南

2指南评论

@midori I see you delete the speaker's page (https://zh.ifixit.com/Item/History/speak...) , which is a very important part in this guide.

Can you explain why you do so? or where can I upload the photo of the speaker?

chair - 回复 分享

Hey, @midori , since you does not explain your deletion, I recover the old speaker page (speaker module for unihertz atom). Please tell me if it is not appropriate.

chair - 回复 分享