跳转到主内容

Repair information, service manuals, and troubleshooting help for refrigerators manufactured by LG Electronics.

122 个问题 查看全部

Refrigerator not cooling, already changed some parts and nothing?

I have a LG French Door refrigerator with freezer on the bottom (LFXS29766S/00) that is not cooling.

The lights and digital buttons all work. On the back, the compressor makes a humming sound and does not get hot. The condenser fan is blowing air towards the compressor. The condenser coils are clean.

I was diagnosed a faulty board which I ordered and changed myself but it didnt fix cooling and everything stayed the same. Once again I was diagnosed a faulty compressor start relay which I ordered and changed myself to the same results.

What else could it be? When its plugged in and I open the top doors or the freezer drawer I dont fell any air circulating at all which led me to think it might be the evaporator fans motors? But it could also be that since I’m opening the doors the fans stop automatically?

From the described symptoms and supposed fixes that havent been it, what could it be?

I have been 2 weeks without refrigerator and its a nightmare…Thanks!

回答此问题 我也有这个问题

这是一个好问题吗?

得分 0

1条评论:

I connected the panel containing the evaporator fans and the drawer railing that contains the "door closed" trigger. When I put the magnet to it, it indeed gets tricked into thinking the drawer is closed and the lights turn off and after 5 seconds the evaporator fans both turn on.

I still dont know whats wrong but it is not the evaporator fans.

On another note, the evaporator coils (inside the freezer) do not get cold at all. This is obviously the problem but I dont know any of this in order to identify the culprit?

完成的

添加一条评论

1个答案

Use a cheap IR gun to check the compressor temperature and let us know your results:

IR Thermometer

Measuring Temperature

It's difficult to measure the temperature inside the compressor, but you can get a fairly accurate idea by measuring the temperature of the discharge line about 6 inches away from the compressor. The temperature of the tubing at this distance is typically 50 to 75 degrees lower than inside the compressor. The safe range for this temperature is below 225 degrees.

IR Thermometer图片

产品

IR Thermometer

$23.99

这个答案有帮助吗?

得分 0
添加一条评论

添加你的答案

Moropo 将永远感激不已
浏览统计数据:

过去 24 小时: 0

过去 7 天: 0

过去 30 天: 1