Can UP3/E function on slow speed with SCS?

I have installed a Speed Control System together with my UP3/E pump. Normal speed, pump is working perfect. When I select slow speed, the pump is pumping slowly for a while until it stops completely and it will not pump again until I press reset button. LED is steady red as from the moment I select low speed. When pumping the red and blue led blinks alternatively. When I select the high speed again, the pump is working perfect again. My question: Does someone recognize what I wrote down? Is the SCS compatible with the UP3/E or is it maybe not?

已回答! 显示答案 我也有这个问题

这是一个好问题吗?

得分 0
添加一条评论

1个答案

已选择的解决方案

Hi @martijn24144

According to the user manual: "The electronic pressure sensor, through the use of a microprocessor, controls the pump’s speed to obtain the needed flow rate ......".

I assume that this would mean that if the flowrate is insufficient then the pump will be shut down.

There is a graph on p.14 showing the flowrate which may help.

You may have to adjust the SCS so that at low speed it still supplies sufficient power for the pump to provide the minimum flowrate

这个答案有帮助吗?

得分 1

1条评论:

Thank you very much! This was indeed the solution of the problem👍🏻