跳转到主内容

Self-priming automatic electric pumps with helical gears, produced by Marco.

28 个问题 查看全部

Any special measures required to start a brand new pu ichmp?

I just installed a brand new UP3/E. When I switch on power, nothing happens at all. No LED shows any light, no sound from the pump. It is definetely filled with water, except the upper half of the inlet filter. When I loose the front plate, water pours out. Same with the bleed screw. The cabling is correct, as my old pump ist working fine on the very same connections. Is it dead on arrival, or what may I need to do to start the pump for the first time?

BTW, the manual mentions situations where a reset may be required, but seems not to explain how to perfom one. So how does it work?

已回答! 显示答案 我也有这个问题

这是一个好问题吗?

得分 0
添加一条评论

1个答案

已选择的解决方案

Hi @saschaottolski

Have you verified that the required voltage is at the pump terminals and that the connections are correct polarity wise?
If so the pump is faulty, get it replaced under warranty.

To reset the pump it only says to disconnect/reconnect the power unless you also have a control panel connected which has a reset button

这个答案有帮助吗?

得分 0

3条评论:

I have LiFePo4 accus, over 13 V. Polarity is correct, and 2 other pumps operate just fine on the very same connections. I can't really imagine such a pump leaves the factory w/o quality control, therefore I hope there might be some kind of trick for a first start.

完成的

@saschaottolski

As you are not getting any indication from the pump that there is power connected i.e. no LEDs of any colour operating at all, pump not trying to operate etc, I can only suggest that if you have a digital multimeter that you disconnect the power from the pump and use the meter's Ohmmeter function to measure the resistance between the red wire and the black wire of the pump.

You should see a resistance value of some sort (don't know the value though) but if the meter registers OL or infinite Ohms i.e. open circuit, then there's a problem in the pump.

完成的

Embarrassing, my apologies for wasting anyone's time. Actually it was indeed the polarity. Two of three pumps didn't care. Thanks a lot for pointing me in the right direction.

BTW, there is indefinite ohmic resistance between plus and minus directly at the pump, with either polarity.

完成的

添加一条评论

添加你的答案

Sascha Ottolski 将永远感激不已
浏览统计数据:

过去 24 小时: 0

过去 7 天: 0

过去 30 天: 3

总计 46