跳转到主内容

Created November 5, 1955, by Doc Brown Enterprises

3 个问题 查看全部

My bath fan flux capacitor is interfering with my takion array.

Panasonic bath fan / light is not working. Model # FV-11VQL4 Light works but fan does not. Switched out the condenser. Still not working. Would rather not spend $300 on a new one.

Please call 858-357-7647

已回答! 显示答案 我也有这个问题

这是一个好问题吗?

得分 0
添加一条评论

1个答案

已选择的解决方案

Hi @bca1962

Here's the wiring diagram for the unit from the service manual.

Use an Ohmmeter to check if the fan motor winding is OK or burnt out.

If the motor is faulty the part number is FFV3700234S (I think). Check on fan motor to verify. There is a parts list in the manual but it is for 3 models and maybe I linked the wrong number.

If the motor is faulty search online using the part number only to find suppliers that suit you best.

Is the interference still there with only the light on? If so it may be the ballast for the light. Happens sometimes with fluorescent lighting

这个答案有帮助吗?

得分 2
添加一条评论

添加你的答案

Tom B 将永远感激不已
浏览统计数据:

过去 24 小时: 0

过去 7 天: 2

过去 30 天: 3

总计 65