After switch on: priming star for few seconds then E05 error

Dear,

Circuit priming message loops at beginning, then straigth away E05 error and asking to restart the machine, I did few times without sucess.

I opened the machine, and I can`t see any leak.

Any recommendation please?

My  coffee machine is Royal gran crema

已回答! 显示答案 我也有这个问题

这是一个好问题吗?

得分 0
1条评论

Hi . The problem with E05 is generated of many SAECO coffee machine , I had this problem and I fixed it . See the video below and I am sure it will helps you .

https://youtu.be/0YR-xtacx1U

完成的

添加一条评论

1个答案

已选择的解决方案

Error code 05 means that the flow meter does not give a signal. Now you have to search: is the flowmeter blocked or broken? Or the water cannot pass through, e.g. because the heater or the pump is calcified. In Saeco Royal Pumpe austauschen the flowmeter can be seen in step 6, picture 2. Open the flowmeter and clean it, it's easy.