Annoying 3-speed fan issue after replacing capacitor

I’ve just replaced the capacitor on my 3-speed floor-standing fan, and while it starts and runs fine on speed 1, if you try and start it on speeds 2 or 3 it acts like the capacitor’s bad, i.e. you can hear the motor but the blades barely move and you have to spin them by hand to get them working.

If you start it on speed 1, you can then switch to speeds 2 or 3 with no problems.

Any ideas as to why it’s behaving like this?

Sure, an obvious workaround it always to start it on speed 1, but before the old capacitor started failing you could start it on any speed and it worked normally.

回答此问题 我也有这个问题

这是一个好问题吗?

得分 0
添加一条评论

1个答案

最有帮助的答案

Are you sure it’s an identical capacitor? The farads is the capacity,the voltage rating is the max it can handle before breaking down. For ex

20 volt cap

1,5,7,10 volts,20 volts,all good

25 volts,bad.

it could be bad or a lower capacitance than the original.

这个答案有帮助吗?

得分 1