Diode testing and other components
Hello,
I have a Macbook Air A1466 (EMC2559). This machine had liquid damage from a large Gator Aid. After much manual cleaning I was able to get it to boot but no display. I further found that the fuse F9700 is blown. I also found that the lcd cable and connecter have been severely burned and both must be replaced. Further investigation shows there is a short at C9017. As I have been checking all the circuits I checked D9701 RB160M-60G (has a 76 on it). I did a diode test and found the following
Forward bias multimeter reads 200 Ohms
Reverse bias multimeter reads 470 Ohms
Both measurements on a Fluke meter in Diode Test mode. I also did a resistance test Forward 8K Ohms, Backward 30K Ohms. Is it safe to say this diode needs to go too?
1条评论
I have learned that a shorted capacitor C9017 in this case, can cause faulty readings. I have ordered a replacement capacitor and will see what happens. Still looking for guidance though.
由 Kardacian 完成的