Why my boiler valves leaks?

My Saeco Incanto Deluxe s class is leaking from the boiler valve, after every cup of coffee that is being made. It would make a hissing sound, some steam would deploy and then clear water would leak. Since it started, the steam wand won't produce any steam. I have descaled the machine, and opened it up, but couldn't find any wetness or leaks from the instant hot or boiler. What could this be?

已回答! 显示答案 我也有这个问题

这是一个好问题吗?

得分 1
添加一条评论

2个答案

已选择的解决方案

Hi @simple7 ,

Don't know your machine at all but was wondering if this link may be of interest to you. "O" rings are usually meant to stop leaking from connections in water systems. ;-)

Here is a link to a supplier if this is the problem. It is not a recommendation to use them.

Update (01/03/2018)

Hi Jack,

I have found the service manual for your machine type (I think).

On p.2-9 it shows a block diagram of the water system for an Incanto S-Class De-Luxe. It shows the relief valve being connected at the pump not the boiler, so unless it is physically mounted on the boiler inlet and not on the pump outlet I'm wondering what valve you are referring to.

Going quickly through the manual it appears that the HWS valve controls the water and steam dispensing function. It also states that if there is no steam coming out of the wand it may be blocked and needs to be cleared using a needle.

Hopefully you may be able to take it further with the help of the manual.

这个答案有帮助吗?

得分 2

5条评论:

Thanks a lot @jayeff, I have replaced that O ring few months ago, as part of my routine upkeep of the machine. My leak comes from the pressure valve in the boiler, and that won't allow for the steam wand to work properly. I just don't know why pressure will build up in the first place.

完成的

Hi @simple7 ,

It's not the valve itself that's the problem?

完成的

Hi @jayeff

I think the valve leak is only the consequence of a build up steam somewhere. If I understand correctly, the relief is through that valve.

完成的

Hi @simple7 ,

What I meant was that the valve was faulty, i.e. continually open, even partially, (you say that there is a hissing sound I assume coming from the valve). Therefore there couldn't be a build up of "pressured" steam to come out of the wand. The water leak from the valve (depending on how much) might be just condensation of the "steam" that passes through it because it is open.

I agree that it should be a relief valve which means that it should only be open when the rated pressure is exceeded and fully closed the rest of the time.

完成的

Hi @jayeff

Yeah, it does make sense that the problem

Is caused by a faulty valve, and that would explain the lack of steam from the wand. However, there’s a release of steam and water from the boiler valve after every coffee shot.

Do you know how the actual boiler valve works?

Thanks again for your help.

完成的

添加一条评论

I think that one of the pipes is in a bad condition and that's why it leaks.You'd better replace them all and see if the problem dissapeares. I'm sure that after this procedure your problem will disappear. This is not very difficult but you have to do it. I bought the valve manufacturer usa and it solved my problem. ANIX Sanitary Butterfly Valves manufactured and distributed by ANIX Valve USA are made of Stainless Steel 316L Material with the options of pull handle, trigger handle, clamp end and butt weld end connection. Wide variety of sanitary fittings will be available.

这个答案有帮助吗?

得分 0
添加一条评论