The compressor failed after little over 3 years

I have the same LG. The compressor failed after little over 3 years. 3 months after replacing the compressor, the fresh food is warm and but the freezer is around 0F. Since it is a dual evaporator system with single compressor, could it be the 3way check value that is switching between the evaporator?

已回答! 显示答案 我也有这个问题

这是一个好问题吗?

得分 0
1条评论

Johan hay, have you looked at the fresh food evaporator? Is there any ice on it?

完成的

添加一条评论

1个答案

已选择的解决方案

Johan hay, Yes it could be that 3 way valve. Most cycle from one evaporator to the other every 15 minutes +-

这个答案有帮助吗?

得分 3
添加一条评论