Before you begin, determine if the pump(s) require replacement. Fill the reservoir with some water, turn the Rug Doctor on to the carpet mode and press the spray button.
Diagnosis
  • Before you begin, determine if the pump(s) require replacement. Fill the reservoir with some water, turn the Rug Doctor on to the carpet mode and press the spray button.

  • For single-pump models (Mighty Pro, X3), if the Rug Doctor does not spray at all, the pump requires replacement.

  • If it sprays inconsistently, check the spray nozzles for clogs first.

  • For the Wide Track model, if the Rug Doctor does not spray at all, both pumps require replacement.

  • If water splashes out of the nozzles for the Wide Track model but does not spray adequately, check the spray nozzles for clogs first.

  • If the nozzles are clear, one of the two pumps may be defective, not supplying sufficient pressure to the nozzles. If possible, replace both pumps.

  • If you need to determine which of the two pumps requires replacement, switch the Rug Doctor on to the upholstery mode. Do not disconnect the quick-connect for accessories. If water splashes out of the nozzles like the carpet mode, replace the front pump.

  • If water does not splash out of the nozzles in accessory mode, replace the rear pump.