简介

If simple sensor maintenance fails to solve the problem with your dryer, replacement may be necessary. This guide details steps taken for replacement of the sensor board for the World Dryer Airforce J4-973A3.

  1. In order to change the air filter, start with the removal of the outer metal casing.
    • In order to change the air filter, start with the removal of the outer metal casing.

    • Using the special bit, remove the large screws at the bottom of the casing.

    • To remove the case, lift the indicated spot with your hands.

    • The direction for turning the screws is different than what was indicated on the small sticker above the hole.

    添加评论

  2. Remove the 1/2" Ph1 screws at the bottom of the red fan cap.
    • Remove the 1/2" Ph1 screws at the bottom of the red fan cap.

    • Turn over the unit.

    • Push the red tabs on the back of the unit with medium to heavy pressure, using a plastic opening tool.

    • Carefully remove the cap, to prevent damage to the sensor.

    添加评论

  3. 传播 Fixmas 欢乐
    Get $12 off your purchase of $50 or more with code FIXMAS12
    传播 Fixmas 欢乐
    Get $12 off your purchase of $50 or more with code FIXMAS12
    • Remove both 3/8" Ph2 screws attached to the grey belt at the top and bottom.

    • Lift the grey belt away. This gives access to the server board.

    添加评论

    • Remove the rainbow ribbon cable from the middle circuit board, using a plastic opening tool.

    • Remove the 1/2" Ph1 screw from the center of the circuit board.

    添加评论

    • Carefully remove the sensor board from your device.

    添加评论

结论

To reassemble your device, follow these instructions in reverse order.