  1. Wolf Gourmet WGBL100S Control Board Replacement, Control Board: 步骤 1 中的图像 1,2 Wolf Gourmet WGBL100S Control Board Replacement, Control Board: 步骤 1 中的图像 2,2
    • Flip the base of the blender upside-down.

    • Remove the four 1/2" long screws in the corners of the base using a Phillips #2 screwdriver.

  2. Wolf Gourmet WGBL100S Control Board Replacement: 步骤 2 中的图像 1,2 Wolf Gourmet WGBL100S Control Board Replacement: 步骤 2 中的图像 2,2
    • Using the metal spudger, pry off one half of each rubber foot.

    • Note that one side of the foot is glued down; pry off the other side.

  3. Wolf Gourmet WGBL100S Control Board Replacement: 步骤 3 中的图像 1,1
    • Using the same screwdriver, remove the next four 1/2" long screws in the holes under the feet.

    • Pull the base off of the blender.

  4. Wolf Gourmet WGBL100S Control Board Replacement: 步骤 4 中的图像 1,2 Wolf Gourmet WGBL100S Control Board Replacement: 步骤 4 中的图像 2,2
    • Pull off the plastic housing.

  5. Wolf Gourmet WGBL100S Control Board Replacement: 步骤 5 中的图像 1,2 Wolf Gourmet WGBL100S Control Board Replacement: 步骤 5 中的图像 2,2
    • Using the same Phillips #2 screwdriver, remove the two 3/4" long screws holding the control board in place.

  6. Wolf Gourmet WGBL100S Control Board Replacement: 步骤 6 中的图像 1,2 Wolf Gourmet WGBL100S Control Board Replacement: 步骤 6 中的图像 2,2
    • Using pliers, pull off all the connectors on the top.

  7. Wolf Gourmet WGBL100S Control Board Replacement: 步骤 7 中的图像 1,1
    • Pull or pry off the last connector block, then remove the control board.

结论

To reassemble your device, follow these instructions in reverse order.