跳转到主内容

Repairing Philips Sonicare HX6711 HealthyWhite 710 Actuator

你所需要的

  1. Repairing Philips Sonicare HX6711 HealthyWhite 710 Actuator, Prepare your tools.: 步骤 1 中的图像 1,1
    • You will need two screwdrivers:

    • a 6.5mm flathead and

    • a small Phillips #1.

  2. Repairing Philips Sonicare HX6711 HealthyWhite 710 Actuator, Open the enclosure: 步骤 2 中的图像 1,3 Repairing Philips Sonicare HX6711 HealthyWhite 710 Actuator, Open the enclosure: 步骤 2 中的图像 2,3 Repairing Philips Sonicare HX6711 HealthyWhite 710 Actuator, Open the enclosure: 步骤 2 中的图像 3,3
    • Have a look to an alternative opening procedure.

    • Take the flathead screwdriver.

    • Insert it into the slot located at the bottom of the handle and turn counterclockwise to release the bottom cap.

    • The second image shows the amount of turning needed to loosen the bottom cap.

    • Be careful with this as the plastic is not very solid. Deforming the material could result in issues when placing the device onto the charging station.

    • Hold the handle upside down, and push down on the shaft to release the internal components of the handle.

  3. Repairing Philips Sonicare HX6711 HealthyWhite 710 Actuator: 步骤 3 中的图像 1,3 Repairing Philips Sonicare HX6711 HealthyWhite 710 Actuator: 步骤 3 中的图像 2,3 Repairing Philips Sonicare HX6711 HealthyWhite 710 Actuator: 步骤 3 中的图像 3,3
    • Carefully pull the internals out of the casing.

  4. Repairing Philips Sonicare HX6711 HealthyWhite 710 Actuator: 步骤 4 中的图像 1,1
    • Take the small Phillips screwdriver.

    • Tighten the small screw that can be found near the top of the device internals

    • Pro tip: I experienced that the screw comes loose after just a few days if you do not take further actions.

    • Hence, unscrew the screw completely and put some superglue at the end of it. Then tighten it again. This prevents the screw to get loose due to the vibrations.

结论

To reassemble your device, follow these instructions in reverse order. Be sure not to insert the internals of the device twisted. Close the device by using the flathead screwdriver and imposing some pressure upon it. Finally, if the internals are in the enclosure close the device by turning the bottom cap clockwise.

12等其他人完成本指南。

Baschtl

于12/02/12注册

1,525 声望

创作了5篇指南

7条评论

thanks for that one - you rescued ours from a premature trip to the landfill :)

Olaf Draeger - 回复

Great guide. Thanks. I just tried doing this to mine but quickly found that the housing the screw goes into was broken completely in half. I wonder if I JB Weld would be strong enough to hold it together.

chiefbozz - 回复

Excellent guide; a simple fix saves $$ and waste. Thanks!!

David Sands - 回复

Thank you! It's realy help me!

Алексей Жерихин - 回复

Did the superglue tip work longterm? I'm just concerned if this approach fails then the glue residue is a mess along the threads. Send feedback!

Gideon - 回复