This guide will instruct on how to replace a malfunctioning Viewfinder assembly on the RCA CC310.

配件

无需配件。

  1. Slide a spudger between the plastic rail and the metal tab on the left side of the rail.  Push away from the camcorder to release the flap.
    • Slide a spudger between the plastic rail and the metal tab on the left side of the rail. Push away from the camcorder to release the flap.

    • Pushing the viewfinder assembly to the right makes lifting the flap easier.

    • Slide the lifted flap towards the viewfinder assembly until the viewfinder is free from the rail.

    添加评论

  2. Unscrew the 7mm ph#0 screw on the underside where the cable connects.
    • Unscrew the 7mm ph#0 screw on the underside where the cable connects.

    • Lift the plastic where the cable connects off of the viewfinder assembly.

    • Disconnect the cable inside by pulling it apart.

    添加评论

    • Unscrew two 7.0mm ph#0 screws on the underside of the viewfinder assembly.

    • Lift the viewfinder plastic assembly up and remove.

    添加评论

  3. 订单满 $20 免运费
    结账时使用优惠码 BLUEANDBLACK
    订单满 $20 免运费
    使用优惠码 BLUEANDBLACK
    • Flip back the viewfinder access tab.

    • Unscrew the 7.0mm ph #0 screw next to the mirror.

    添加评论

    • Lift off both sides of the plastic assembly.

    • When reassembling, if the housing doesn't connect properly, try turning the focus wheel.

    添加评论

    • Lift the microphone circuit board straight up.

    • Unclip the cable connected to the circuit board.

    添加评论

    • Lift plastic housing and guide the wires from underneath.

    • Lift out the entire circuit board and viewfinder.

    • Replace entire circuit board and viewfinder assembly.

    添加评论

结论

To reassemble your device, follow these instructions in reverse order.