跳转到主内容

Milwaukee Circular Saw 263020 B57A 2008 Back Panel Replacement

你所需要的

  1. Milwaukee Circular Saw 263020 B57A 2008 Back Panel Replacement, Back Panel: 步骤 1 中的图像 1,1
    • Orient your saw sideways so that the blade is facing downwards.

  2. Milwaukee Circular Saw 263020 B57A 2008 Back Panel Replacement: 步骤 2 中的图像 1,3 Milwaukee Circular Saw 263020 B57A 2008 Back Panel Replacement: 步骤 2 中的图像 2,3 Milwaukee Circular Saw 263020 B57A 2008 Back Panel Replacement: 步骤 2 中的图像 3,3
    • Remove the nine 6 mm screws using a Torx T4 screwdriver.

    • Remove the single 8 mm screw at the bottom that attaches the panels together using a Torx T6 screwdriver.

    • Slowly pull and remove the front panel of the saw that connects to the blade side with your hand, and separate it from the motor.

结论

To reassemble your device, follow these instructions in reverse order.