简介

This guide shows you how to replace the spring on the power button.

  1. Turn the device upside down so that the three rubber pads are facing up.
    • Turn the device upside down so that the three rubber pads are facing up.

  2. Use a heat gun (set to low) to apply heat  to one of the rubber pads until you can easily remove the pad. This step takes around 5-7 minutes.
    • Use a heat gun (set to low) to apply heat to one of the rubber pads until you can easily remove the pad. This step takes around 5-7 minutes.

  3. Remove the heated rubber pad with a plastic opening tool.
    • Remove the heated rubber pad with a plastic opening tool.

    • Repeat steps 2 and 3 for the two remaining rubber pads.

  4. 所有超过US$100.00或包含 Pro Tech工具包的订单免费送货!

    浏览我们的商店
  5. Remove the six 1cm T-10 torx screws on the bottom of the device (found under the rubber pads) using a T-10 Torx screwdriver. Remove the six 1cm T-10 torx screws on the bottom of the device (found under the rubber pads) using a T-10 Torx screwdriver.
    • Remove the six 1cm T-10 torx screws on the bottom of the device (found under the rubber pads) using a T-10 Torx screwdriver.

  6. Open the device along its seam. Be careful when separating the device because there are wires connecting the two seperate halves. Be careful when separating the device because there are wires connecting the two seperate halves.
    • Open the device along its seam.

    • Be careful when separating the device because there are wires connecting the two seperate halves.

  7. Disconnect the ribbon cable connector from the top half of the device by pulling outward and parallel to the connecting pins.
    • Disconnect the ribbon cable connector from the top half of the device by pulling outward and parallel to the connecting pins.

  8. Locate and disconnect the two molex connectors found on either side of the ribbon cable connector on the bottom half of the device. Locate and disconnect the two molex connectors found on either side of the ribbon cable connector on the bottom half of the device.
    • Locate and disconnect the two molex connectors found on either side of the ribbon cable connector on the bottom half of the device.

  9. Pull the plastic button off the post. Pull the plastic button off the post.
    • Pull the plastic button off the post.

  10. Remove the metal U-clip (compressing the spring) with tweezers.
    • Remove the metal U-clip (compressing the spring) with tweezers.

结论

To reassemble your device, follow these instructions in reverse order.