跳转到主内容

Honeywell HY-204 Rotation Button Replacement

你所需要的

  1. Honeywell HY-204 Rotation Button Replacement, Case: 步骤 1 中的图像 1,2 Honeywell HY-204 Rotation Button Replacement, Case: 步骤 1 中的图像 2,2
    • Before you begin, be sure to unplug the fan.

    • Remove the four 14 mm screws from the back of the device using the Phillips #0 Screwdriver.

  2. Honeywell HY-204 Rotation Button Replacement: 步骤 2 中的图像 1,2 Honeywell HY-204 Rotation Button Replacement: 步骤 2 中的图像 2,2
    • Pull the front and back parts of the case away from each other until the back is free from the front. This may require a large amount of force.

  3. Honeywell HY-204 Rotation Button Replacement, Control Panel: 步骤 3 中的图像 1,2 Honeywell HY-204 Rotation Button Replacement, Control Panel: 步骤 3 中的图像 2,2
    • Remove the two 3mm screws found just below the top of the device using the Phillips #0 Screwdriver.

  4. Honeywell HY-204 Rotation Button Replacement: 步骤 4 中的图像 1,1
    • Pry off the control panel by forcefully lifting the tab located inside the front of the fan with the plastic opening tool.

  5. Honeywell HY-204 Rotation Button Replacement, Rotation Button: 步骤 5 中的图像 1,2 Honeywell HY-204 Rotation Button Replacement, Rotation Button: 步骤 5 中的图像 2,2
    • Remove the two 10mm Phillips #0 screws that are located next to the rotation button.

  6. Honeywell HY-204 Rotation Button Replacement: 步骤 6 中的图像 1,1
    • Peel back the heat shrink tubing on both wires connecting to the button.

  7. Honeywell HY-204 Rotation Button Replacement: 步骤 7 中的图像 1,1
    • Caution The soldering iron is very hot, be careful to avoid burns.

    • Desolder the two wires connected to the button and remove the button.

结论

To reassemble your device, follow these instructions in reverse order.