跳转到主内容

Honda 3000 Watt Generator EB3000CK2A Circuit Breaker Replacement

你所需要的

  1. Honda 3000 Watt Generator EB3000CK2A Circuit Breaker Replacement, Disconnect the spark plug: 步骤 1 中的图像 1,2 Honda 3000 Watt Generator EB3000CK2A Circuit Breaker Replacement, Disconnect the spark plug: 步骤 1 中的图像 2,2
    • Before you begin, disconnect the spark plug connector from the spark plug.

  2. Honda 3000 Watt Generator EB3000CK2A Circuit Breaker Replacement, Remove the control box cover panel: 步骤 2 中的图像 1,1
    • Use a Phillips #2 screwdriver to remove the five 15 mm screws securing the control box cover.

  3. Honda 3000 Watt Generator EB3000CK2A Circuit Breaker Replacement: 步骤 3 中的图像 1,3 Honda 3000 Watt Generator EB3000CK2A Circuit Breaker Replacement: 步骤 3 中的图像 2,3 Honda 3000 Watt Generator EB3000CK2A Circuit Breaker Replacement: 步骤 3 中的图像 3,3
    • Use a flathead screwdriver to pry and loosen the control panel from the control box.

    • Tilt the control panel down so the rear of the panel is accessible.

  4. Honda 3000 Watt Generator EB3000CK2A Circuit Breaker Replacement, Unfasten the circuit breaker: 步骤 4 中的图像 1,1
    • Use a Phillips #2 screwdriver to remove the four 5 mm screws securing the circuit breaker to the control box panel.

  5. Honda 3000 Watt Generator EB3000CK2A Circuit Breaker Replacement: 步骤 5 中的图像 1,3 Honda 3000 Watt Generator EB3000CK2A Circuit Breaker Replacement: 步骤 5 中的图像 2,3 Honda 3000 Watt Generator EB3000CK2A Circuit Breaker Replacement: 步骤 5 中的图像 3,3
    • Carefully pull the circuit breaker away from the panel.

    • This may require a significant amount of force. Take care as the circuit breaker is still wired to the rest of the generator.

  6. Honda 3000 Watt Generator EB3000CK2A Circuit Breaker Replacement, Note circuit breaker pinout: 步骤 6 中的图像 1,1
    • Take note of where each cable connects to the breaker for reassembly.

    • It can be helpful to disconnect and reconnect one cable at a time to the new circuit breaker to maintain cable management and prevent mix ups.

  7. Honda 3000 Watt Generator EB3000CK2A Circuit Breaker Replacement, Disconnect the circuit breaker: 步骤 7 中的图像 1,2 Honda 3000 Watt Generator EB3000CK2A Circuit Breaker Replacement, Disconnect the circuit breaker: 步骤 7 中的图像 2,2
    • Disconnect the large white connector from the circuit breaker.

    • Take note of the orientation of the connector in relation to the breaker for reassembly.

  8. Honda 3000 Watt Generator EB3000CK2A Circuit Breaker Replacement: 步骤 8 中的图像 1,3 Honda 3000 Watt Generator EB3000CK2A Circuit Breaker Replacement: 步骤 8 中的图像 2,3 Honda 3000 Watt Generator EB3000CK2A Circuit Breaker Replacement: 步骤 8 中的图像 3,3
    • Disconnect the two spade crimp connectors from the breaker.

    • This may require a significant amount of force. If you are having trouble, you can use pliers to grip the connectors. Pull only on the blue crimp connector, not the actual wire.

  9. Honda 3000 Watt Generator EB3000CK2A Circuit Breaker Replacement: 步骤 9 中的图像 1,2 Honda 3000 Watt Generator EB3000CK2A Circuit Breaker Replacement: 步骤 9 中的图像 2,2
    • Use a Phillips #2 screwdriver to remove the two 6 mm screws securing the cables to the terminals on the breaker.

  10. Honda 3000 Watt Generator EB3000CK2A Circuit Breaker Replacement, Remove the circuit breaker: 步骤 10 中的图像 1,1
    • Remove the circuit breaker.

结论

To reassemble your device, follow these instructions in reverse order.

Tarun Thiruma

于11/20/19注册

35,516 声望

创作了134篇指南

一条评论

I have a Honda gen. EM500SK. It has two double outlet GFCI (total 4 110v plugs). These are sensitive to current/voltage fluctuations and in my case I need at least one of these to be a standard no GFIC which is more reliable than the current outlets. Any idea if I can purchase non GFIC outlets from an earlier model of generator and fit them to my current generator?