Before disassembling the blender base, make sure the blender disconnected from any power outlet.
  • Before disassembling the blender base, make sure the blender disconnected from any power outlet.

  • Lift the jar straight up from the base without tilting the jar.

添加评论

Remove the top three 1/4 inch base screws using a Philip's head screwdriver.
  • Remove the top three 1/4 inch base screws using a Philip's head screwdriver.

添加评论

  • Remove the two base leg covers next to the power cord using pliers or a flat-head screwdriver.

  • This provides access to the base screws beneath.

添加评论

  • Remove the following screws that secure the top and bottom halves of the base.

    • One 1/4 Phillips screw

    • One TA-20 screw

  • Both screwdrivers must have a minimum of a three inch shank (length).

  • Screwdrivers with extenders will not fit down the access holes.

添加评论

  • Lift the top half of the base from the bottom half of the base to reveal the internal mechanism.

添加评论

  • Once you have the base removed, the circuit board should be clearly visible inside.

添加评论

  • Remove the four screws located on the circuit board.

    • Two are on the left side.

    • Two are on the right side.

添加评论

  • Remove the following soldered connections with a soldering iron:

    • Motor wires

    • Power cord wires

添加评论

  • Lift the circuit board straight up to remove it from the base.

添加评论

结论

To reassemble your device, follow these instructions in reverse order.

另外一个人完成了本指南。

Andrew

于2012年10月04日注册

170 信誉积分

创作了4篇指南

团队

Cal Poly, Team 6-34, Regan Fall 2012 Cal Poly, Team 6-34, Regan Fall 2012 的会员

CPSU-REGAN-F12S6G34

4 名成员

创作了6篇指南

添加评论

浏览统计数据:

过去的24小时: 1

过去的7天: 3

过去的30天: 38

总计 2,599