跳转到主内容

本指南有最近更改,您可查看未经巡查的最新版本

Angelcare AC401 Baby Monitor Disassembly

你所需要的

  1. Angelcare AC401 Baby Monitor Disassembly, Angelcare AC401 Baby Monitor Disassembly: 步骤 1 中的图像 1,2 Angelcare AC401 Baby Monitor Disassembly, Angelcare AC401 Baby Monitor Disassembly: 步骤 1 中的图像 2,2
    • first remove the 2 screws at the green plastic plate.

  2. Angelcare AC401 Baby Monitor Disassembly: 步骤 2 中的图像 1,1
    • remove the plastic plate ( battery compartment)

    • you'll see that there are 2 more screws. Remove them.

  3. Angelcare AC401 Baby Monitor Disassembly: 步骤 3 中的图像 1,2 Angelcare AC401 Baby Monitor Disassembly: 步骤 3 中的图像 2,2
    • now gently remove the green plastic plate arrounf the baby monitor ( arround the screen) use a spudger to click it open.

  4. Angelcare AC401 Baby Monitor Disassembly: 步骤 4 中的图像 1,2 Angelcare AC401 Baby Monitor Disassembly: 步骤 4 中的图像 2,2
    • now open the monitor by clicking it open or slide it open. Sometimes its easier to use a spudger.

    • be carefull for the electric wires.

  5. Angelcare AC401 Baby Monitor Disassembly: 步骤 5 中的图像 1,2 Angelcare AC401 Baby Monitor Disassembly: 步骤 5 中的图像 2,2
    • 2 battery's were exploded so the acid was on the black electric power wire.

    • use a cotton swab with a little bit of destilled water.

  6. Angelcare AC401 Baby Monitor Disassembly: 步骤 6 中的图像 1,1
    • remove the 2 PCB's by removing the screws shown in the picture.

  7. Angelcare AC401 Baby Monitor Disassembly: 步骤 7 中的图像 1,1
    • pull the first PCB up and remove the screws of the second PCB.

    • after removing the two PCB's, clean the acid on the PCB.

    • after cleaning the PCB's put it al together again.

    • first remove the battery lid. 1 screw.

    • slide it out like you see in picture

    • remove battery's

结论

To reassemble your device, follow these instructions in reverse order.

6等其他人完成本指南。

Kevin D

于05/02/14注册

7,276 声望

创作了21篇指南

13条评论

Thanks for this. I couldn't figure out how to get the blue clip off without breaking it to clean some dirt on the screen. Googled it, found this, job done.

Pete H - 回复

Sometimes the activity of the reference quartz is 11,150 MHz, and the devices do not find each other.

I have so repaired the parent module.

Dmitriy, the city of Volzhsky.

Dmitriy N - 回复

Hi Dimitriy - I am experiencing the issue with not finding devices each other. How have you fix it ? Is it a matter of replacing the reference quartz with new one ?

Jan - 回复

Hi. At my Angelcare (AC401) parent unit the screen has slowly become worse and worse. At first, parts of the temperature figures dissapeared, then the symbols around and now I no longer see anything... But the unit still works! (And alert me if the baby's crying) What do you think, is there anything I can do or do I need to buy a new one?

Terese Rehn - 回复

Hi There. I’m having the same problem. Did you find a fix or did you buy a new unit?

Eugene -

添加评论

浏览统计数据:

过去 24 小时: 3

过去 7 天: 8

过去 30 天: 24

总计 14,823