跳转到主内容

Repair guides and support for all-in-one washer and dryer assemblies as well as stacked units.

140 个问题 查看全部

Using schematic diagram and wires how can I figure out why washer can'

Friddgedair combo used- washer wont run after water level fill sensor reached unless dryer start button pushed. How to check wiring for washer to run separately from dryerFriddgedair combo used- washer wont run after water level fill sensor reached unless dryer start button pushed. How to check wiring for washer to run separately from dryer

回答此问题 我也有这个问题

这是一个好问题吗?

得分 0

3条评论:

Hi,

What is the model number of the combo unit?

Has it worked OK for you before?

完成的

Fridgedair flxe52rbs8

完成的

According to person bought from yes. Only change I made was switching 4 prong cord to 3 prong for our current outlet.

完成的

添加一条评论

1个答案

Hi @April Taylor

Just confirming that the 3 prong wall outlet is a 240 V AC supply installed for the combo unit i.e. 2 x 120V active wires, each supply separately fused in the power box and a Neutral wire and not that it is the standard household 3 prong outlet of 1 x 120V active, 1 x Neutral and 1 x earth

Note: At least one of the 120V power supplies to the wall outlet needs its own fuse. The other 120V supply can be connected to the same fuse as the other wall outlets in that area of the premises

Here's the user manual that describes the electrical connections - see p.7 that may help.

这个答案有帮助吗?

得分 0

2条评论:

Yes. We have lived here for 16 yrs and have had front load sets as well as another fridgedair unit with no issues such as this one.

完成的

@April Taylor

OK, but did those units require 120V AC or 240V AC to work? The combo unit requires 240V AC

You need to check that there is 240V AC between the 2 Active pins of the wall outlet socket that the combo unit is connected to

If there is 240V AC between the 2 Active pins then check that there is 120V AC between each Active pin and the Neutral pin in the socket. This is to make sure that the Neutral wire is OK

If there is no 240V then do the 2nd test above to check which 120V AC supply is missing.

Be safety aware: If you don't know how to test potentially lethal AC voltage safely, then don't do it! Call an electrician

完成的

添加一条评论

添加你的答案

April Taylor 将永远感激不已
浏览统计数据:

过去 24 小时: 0

过去 7 天: 1

过去 30 天: 4

总计 47