Kenmore HE3t Electric Dryer - No heat - Some parts replaced

I have a Kenmore HE3t electric dryer, model 110.84836201 that is not heating.

Air is blowing, drum tumbles, timer counts down, no problems.

Replaced the heating element, thermal fuse, thermistor - problem persists. Had all parts checked and the parts are good. What am I missing?

Update (02/25/2019)

Updating…

  • Circuit breaker only has one switch for the dryer, clicked it off and on, no change with the dryer.
  • Tested the outlet and the voltage is correct.
  • Tested the power cable and connectors, voltage is correct.
  • Dismantled the tinfoil vent tube thing and cleaned it, also checked the vent orifice on the house itself.
  • To date, these parts have been verified as working or flat out replaced: heating element, thermal fuse, thermistor, high limit thermosat, cut off fuse (I think that’s what it’s called, the one that comes with the thermostat).

The dryer is still running as normal without heat. Air is blowing, timer is working correctly. I ran the dryer for 20 minutes, dismantled it, and the heating element was cool to the touch - shouldn’t it be warm? I’m assuming something isn’t telling the heating element to click on.

Waiting on a control board to arrive in the mail.

Update (02/28/2019)

Update 2/28/19

I received the dryer control board in the mail and have replaced that, and the dryer is now heating! Yay!

Of the original parts, the heating element, high limit thermostat and thermistor were all damaged. I replaced all of those and I replaced the thermal fuse and cutoff fuse because it came with the kits I ordered. There must have been a short either from a power surge or just the control board dying and it had a chain reaction and blew out several pieces.

已回答! 显示答案 我也有这个问题

这是一个好问题吗?

得分 0
添加一条评论

2个答案

已选择的解决方案

Hi @tryin2fixit ,

Did you check that the hi limit thermostat is OK?

这个答案有帮助吗?

得分 2
添加一条评论

The two you missed are

Cause 1

Incoming Power Problem

If your dryer is not heating, then you may have an incoming power problem. Electric dryers need two legs of 120 volts AC equaling 240 volts. It is not uncommon for only one fuse or breaker to trip resulting in the dryer able to run, but not heat. The fuse box or circuit breaker should be checked or voltage measured at the outlet using a multi-meter.

Cause 2

High Limit Thermostat

High limit thermostat, L295-50F

https://www.repairclinic.com/PartDetail/...

The high-limit thermostat monitors the dryer temperature and shuts off the burner if the dryer overheats. If the high-limit thermostat is malfunctioning, it may shut off the burner even if the dryer is not overheating. However, this is rarely the case. Before replacing the high limit thermostat check all the more commonly defective parts. If you have determined that all of the other components are working properly, test the thermostat by using a multimeter to test it for continuity. If the thermostat does not have continuity, replace it.



这个答案有帮助吗?

得分 2
添加一条评论