跳转到主内容

The Kenmore Elite HE3 is 7.2 cu. ft. capacity electric dryer by Kenmore.

318 个问题 查看全部

Smell fire in dryer

I was doing laundry the other day...when I noticed my clothes were not drying I put them on another cycle but again damp and I could smell popcorn type burning. We had the ducts cleaned but it is still smelling like burnt...any idea why

已回答! 显示答案 我也有这个问题

这是一个好问题吗?

得分 0
3条评论

It's a gas dryer...we disconnected it.

完成的

Thanks Geoff I added a comment below

完成的

My husband is thinking he doesn't want to touch the gas..he found black like silt or ash near the screen inside the dryer

完成的

添加一条评论

2个答案

已选择的解决方案

Cause 1

Thermal Fuse

The thermal fuse is a safety device designed to protect the dryer from overheating. The fuse is located on the blower housing or at the dryer’s heat source such as the heating element on electric dryers or at the burner on gas models. The fuse should be closed for continuity meaning it has a continuous electrical path through it when good. If overheated the fuse will have no continuity meaning the electrical path is broken and the fuse has blown. A multimeter can be used to test it for continuity. Be aware that a blown thermal fuse is an indication of a restricted exhaust vent from the dryer to the outside. Always check the dryer venting when replacing a blown thermal fuse.

Cause 2

Gas Valve Solenoid

Gas dryers have two or more gas valve solenoid coils. The gas valve solenoids open the gas valve ports to allow gas to flow into the burner assembly. If a gas valve solenoid fails, the dryer won’t heat. To determine if one or more of the gas valve solenoids has failed, check the igniter. If the igniter glows and goes out but does not ignite the gas, the gas valve solenoid is defective. If one or more of the gas valve coils are defective, we recommend that you replace them as a set.

Cause 3

Igniter

The igniter uses heat to ignite the gas in the burner assembly. If the igniter is not working, the gas will not ignite, preventing the dryer from heating. To determine if the igniter has burned out, use a multimeter to test the igniter for continuity. If the igniter does not have continuity, replace it.

这个答案有帮助吗?

得分 2
添加一条评论

It's almost definitely a lint buildup causing poor airflow. I am actually surprised that a thermal fuse didn't break. Even if the ducts are cleaned, the fan blades will hold onto a fair amount of lint. I would suggest checking there first. Most dryers I have disassembled have a cover plate over the fan assembly in the rear of the appliance, but some require a little more disassembly to get to the fan. If you can give us an exact model number, we might be able to help diagnose further.

这个答案有帮助吗?

得分 1

1条评论:

My husband doesn't want to get in there due to gas hookup...it's a kenmore 592-99327. There was like black ash near the dryer screen at the back of the drum...sounds like your right...

完成的

添加一条评论

添加你的答案

lisamf1978 将永远感激不已
浏览统计数据:

过去 24 小时: 1